logo
Ana sayfa ÜrünlerToksin test kitleri

High Ssensitivity Microcystins ELISA Test Kit

Ben sohbet şimdi

High Ssensitivity Microcystins ELISA Test Kit

High Ssensitivity Microcystins  ELISA Test Kit
High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit

Büyük resim :  High Ssensitivity Microcystins ELISA Test Kit

Ürün ayrıntıları:
Menşe yeri: ÇİN
Marka adı: Chenhui
Model numarası: CH98018
Ödeme & teslimat koşulları:
Min sipariş miktarı: 1KIT
Fiyat: negotiable
Ambalaj bilgileri: Renk paketleme
Teslim süresi: 5-8 İş Günü
Ödeme koşulları: T/T
Yetenek temini: 1000 takım

High Ssensitivity Microcystins ELISA Test Kit

Açıklama
Ani: <30 dakika yüksek Kurtarma: %80-105
Tespit süresi: 1 saat Saklama sıcaklığı: 2-8 ° C
Spesifikasyon: 96T Doğrusal aralık: 0,02ng/mL
Vurgulamak:

high sensitivity microcystins ELISA kit

,

microcystins toxin test kit

,

ELISA test kit for toxins

 

Microcystins ELISA Test Kit

 

CH 98018

         

         

Product Description

 

High Ssensitivity Microcystins  ELISA Test Kit 0     The Microcystins ELISA is an immunoassay for the quantitative and sensitive congener-independent detection of Microcystins and Nodularins in water samples.

 

Sample Collection and Handling

Collect water samples in glass or PETG containers and test within 24 hours. Use of other types of plastic collection and/or storage containers may result in adsorptive loss of Microcystins, producing inaccurate (falsely low) results. Drinking water samples should be treated with sodium thiosulfate immediately after collection . If samples must be held for longer periods (up to 5 days), samples should be stored refrigerated. For storage periods greater than 5 days, samples should be stored frozen.

If total Microcystins concentration (free and cell bound) is required, an appropriate cell lysing procedure must be performed prior to analysis.

Note: The use of sonication in cell lysing can negatively affect toxin concentrations, producing falsely low sample results.

Samples may be filtered prior to analysis using glass fiber filters. The use of alternate filter types (non-glass fiber filters) may produce falsely low sample results, as Microcystins may bind to the filter material, removing it from the sample. Also, please note that some glass fiber filters are manufactured using a process which may cause interference which would cause inaccurate (falsely high) results. To avoid this potential bias in sample results, a total volume of at least 10 mL should be passed through the glass fiber filter, with the first 5 mL of filtered sample being discarded and the second 5 mL collected for testing . If determining total Microcystins concentration, samples should be lysed prior to filtration to prevent the removal of cell-bound Microcystins, which would cause inaccurate (falsely low) results.

High Ssensitivity Microcystins  ELISA Test Kit 1

İletişim bilgileri
Maoming Chenhui Biotechnology Co., Ltd.

İlgili kişi: Tina

Tel: +8615818799493

Sorgunuzu doğrudan bize gönderin (0 / 3000)